• 主营产品:二手网络分析仪  二手信号源  二手频谱分析仪  收购二手手机测试电源  回收进口二手仪器  租售手机综合测试仪器  卫星功放  手持频谱分析仪  
产品资料
产品[

Rohde&Schwarz ZVC8 8G网络分析仪罗德与施瓦茨20kHz-8GHz

]资料
如果您对该产品感兴趣的话,可以 sendmsg
产品名称: Rohde&Schwarz ZVC8 8G网络分析仪罗德与施瓦茨20kHz-8GHz
产品型号: Rohde&Schwarz ZVC
产品厂商: 深圳市二手仪器 二手网络分析仪 二手频谱分析仪 二手信号源 微波暗室 屏蔽房 深圳仪器租赁
产品文档: 无相关文档


简单介绍
Rohde&Schwarz ZVC8 8G网络分析仪罗德与施瓦茨20kHz-8GHzZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz 特点 ?20kHz~8GHz频率范围 ?高测量速度(<125μs/测量点) ?低固有噪声(-130dB) ?宽动态范围(>130dB) ?高频率分辨率(10μHz) ?校准时间短(<20s) ?有源彩色LCD(26cm)

Rohde&Schwarz ZVC8 8G网络分析仪罗德与施瓦茨20kHz-8GHz

的详细介绍
Rohde&Schwarz ZVC8 8G网络分析仪罗德与施瓦茨20kHz-8GHz

产品型号: ZVC

产品展商: 盛强电子仪器  白志强 13760339695

简单介绍

Rohde&Schwarz ZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz厂商名称: 德国罗德与施瓦茨Rohde&Schwarz R&S特点 ?20kHz~8GHz频率范围 ?高测量速度(<125μs/测量点) ?低固有噪声(-130dB) ?宽动态范围(>130dB) ?高频率分辨率(10μHz) ?校准时间短(<20s) ?有源彩色LCD(26cm) 技术指标 ?Data only for 50Ω test sets.For 75Ω test sets and further details please refer to data sheet PD 757.1802.23.Unless otherwise stated,specifications apply to test ports PORT 1 and PORT2,a nominal source power of -10dBm at the test port and an IF bandwidth≤10kHz ?The arrow marks i

Rohde&Schwarz ZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz的详细介绍

Rohde&Schwarz ZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz

厂商名称:德国罗德与施瓦茨Rohde&Schwarz R&S

特点

    ·20kHz~8GHz频率范围

    ·高测量速度(<125μs/测量点)

    ·低固有噪声(-130dB)

    ·宽动态范围(>130dB)

    ·高频率分辨率(10μHz)

    ·校准时间短(<20s)

    ·有源彩色LCD(26cm)

技术指标

    ·Data only for 50Ω test sets.For 75Ω test sets and further details please refer to data sheet PD 757.1802.23.Unless otherwise stated,specifications apply to test ports PORT 1 and PORT2,a nominal source power of -10dBm at the test port and an IF bandwidth≤10kHz

    ·The arrow marks important data.

    ·Frequency range,measurement speed,dynamicrange

    ·Frequency range

    ·Without External Measurements option

    ·ZVRL,ZVRE,ZVR

    ·with passive test set 50Ω or 75Ω|9kHz to4Ghz

    ·with active test set 50Ω or 75Ω|300kHz to4GHz

    ·ZVCE,ZVC

    ·with active test set 50Ω|20kHz to 8GHz

    ·With External Measurement option

    ·ZVRL,ZVRE,ZVR|10Hz to 4Ghz

    ·ZVCE,ZVC|20kHz to 8Ghz

    ·Relative frequency    ·deviation|<2*10^-6+1*10^-6/a

    ·Resolution|10μHz

    ·Measurement speed(above 2Mhz)

    ·Number of points|1 to 2001(selectable)

    ·Measurement time per point|IFbandwidth(IFBW)

 

 3kHz10kHz26kHz
with systemerrorcorrection<1.50μs<460μs<330μs
normalized<530μs<230μs<190μs
FastMode
withsystemerror correction--<240μs
normalized--<125μs

 

    ·Dynamicrange(without system error correction)

    ·ZVRL,ZVRE,ZVR

    ·(models ZVRL and ZVRE:at IF bandwidth 10Hzvalues are reduced by 5dB)

 

 IFbandwidth
With passivetest set 50Ω10Hz3kHz10kHz
20kHz to20MHz>65dB,typ.>110dB--
200kHz to20MHz>110dB>90dB>85dB
20MHz to3Ghz>120dB>100dB>95dB
3Ghz to4Ghz>110dB>90dB>85dB
With activetest set 50Ω
300kHz to1Mhz>107dB>87dB>82dB
1MHz to20MHz>110dB>90dB>85dB
20MHz to3Ghz>120dB>100dB>95dB
3Ghz to4Ghz>110dB>90dB>85dB
With ExternalMeasurements option
50Hz to200kHz>75dB--
200kHzto20MHz>110dB>95dB>90dB
20MHz to1Ghz>130dB>110dB>105dB
1Ghz to3Ghz>120dB>100dB>95dB
3Ghz to4Ghz>110dB>95dB>90dB

 

    ·ZVCE,ZVC

    ·(mode ZVCE:at IF bandwidth 10Hz values arereduced by 5dB)

With active test set 50Ω

 

20kHz to200kHz>60dB,--
200kHzto20MHz>100dB>80dB>75dB
20Mhz to3Ghz>120dB>100dB>95dB
3Ghz to4Ghz>110dB>90dB>85dB
4Ghz to6Ghz>105dB>85dB>80dB
6Ghz to8Ghz>100dB>80dB>75dB
WithExternal/Measurements option
20kHz to200kHz>75dB--
200kHz to20Mhz>110dB>95dB>90dB
20MHz to1GHz>130dB>110dB>105dB
1Ghz to3Ghz>120dB>100dB>95dB
3Ghz to4Ghz>110dB>95dB>90dB
4GHz to6GHz>105dB>90dB>85dB
6Ghz to8GHz>100dB>85dB>80dB
Stability ofmeasurement traceper degree temperaturevariationZVRL,ZVRE,ZVR<0.05dBor 0.4°
ZVCE,ZVC<0.1 dB or1°
Measurementbandwidth
(IF bandwidthIFBW)1Hz to 10kHz(half-decade steps)and 26kHz(full)

 

    ·Measurementaccuracy

    ·The following data are validbetween 20℃ and 30℃ provided the instrument has reached thermal equilibrium (about 1 h after switch-on)and the tempera-ture has not varied by more than 1 degree after calibration.

    ·ZVRE and ZVR(bidirectional networkanalyzers)

    ·Accuracy of transmission measurementsafter full two-part system error cor-rection(TOSM)

    ·Specificaitons are based on a matched DUTand refer to a nominal source power of -10dBm at the test port.

    ·With test set 50Ω 300kHz to 4Ghz

at IF bandwidth 10Hz

    ·for+10dB to +3dB|<1dB or 6°

    ·for+3dB to -5dB|<0.2dB or 1°

    ·for -5dB to -60dB(passive|<0.05dB or0.4°

    ·for-5dB to -60dB(active)|0.2dB or 1°

    ·for+3dB to -40dB|typ.<0.025dB

    ·for-60dB to -70dB|<0.2dB or 1°

    ·for-70dB to -80dB(ZVRE)|<1dB or 6°

    ·for-70dB to -85dB(ZVR)|<1dB or 6°

    ·Accuracy of reflection measurements

    ·after system error correction (TOSM orfull one-port)

    ·Specificaitons are based on an isolationgDUT and refer to a nominal source power of-    ·10dBm at the test port.

    ·With test set 50Ω

    ·It is assumed that the return loss of thematch used for calibration is >46dB(effective systemdata:directivity Deff>46dB,test port match Seff>30dB).

    ·20kHz to 4Ghz(passive test set),

    ·300kHz to 4GHz(active test set)

    ·for+10dB to +3dB|<1dB or 6°

    ·for+3dB to -15dB|<0.4dB+0.04dB/Ghz,<3°+0.4°/Ghz

    ·for-15dB to -25dB|<1dB or 6°

    ·for-25dB to -35dB|<3dB or 20°

    ·ZVCE and ZVC

    ·Accuracy of transmission measurements

    ·after full two-part system errorcorrection(TOSM)

    ·Specifications are based on a matched DUTand refer to a nominal source power of -20dBm at the test port.

    ·10MHz to 4Ghz

    ·at IF bandwidth 10Hz

    ·for +10dB to +3dB|<1dB or 6°

    ·for+3dB to -50dB|<0.2dB or 1°

    ·for+3dB to -40dB|typ.<0.025dB

    ·for-50dB to -60dB|<0.5dB or 4°

    ·for-60dB to -70dB(ZVCE)|<1dB or 6°

    ·for-60dB to -75dB(ZVC)|<1dB or 6°

4Ghz to 8Ghz

    ·at IF bandwidth 10Hz

    ·for+10dB to +3dB|<1dB or 6°

    ·for+3dB to -45dB|<0.2dB or 2°

    ·for+3dB to -40dB |typ.<0.025dB

    ·for-45dB to -55dB(ZVCE)|<1dB or 6°

    ·for-45dB to -60dB(ZVC)|<1dB or 6°

    ·Accuracy of reflection measurements

    ·after system error correction (TOSM orfull one-port)

    ·Specifications are based on an isolaitngDUT and refer to a nominal source power of -20dBm at the testport.

    ·It is assumed that the return loss of thematch used for calibration is >40dB(effective systemdata:directivity Deff>40dB,test port match Seff>30dB).

    ·20kHz to 8Ghz

    ·for+10dB to +3dB|<1dB or 6°

    ·for+3dB to-    ·10dB|<0.4dB+0.04dB/GHz,<3°_0.4°/Ghz

    ·for=\-10dB to -20dB|<1dB or 6°

    ·for-20dB to -30dB|<3dB or 20°

    ·ZVRL(unidirectional network analyzer)

    ·Accuracy of transmission measurements

    ·after system error correction (one-pathtwo-port)

    ·Specifications are based on a matched DUTand refer to a nominal source power of -10dBm at the test port.

    ·With test set 50Ω

    ·It is assumed that the return loss of thematch used for calibration is >46dB(effective systemdata:directivity Deff>46dB,test port match Seff>30dB).

    ·20khz to 4Ghz

    ·for+10dB to +3dB|<1dB or 6°

    ·for+3dB to -15dB?|<0.4dB+0.04dB/Ghz,<3° +0.4°/Ghz

    ·for-15dB to -25dB|<2dB or 6°

    ·for-25dB to -35dB|<3dB or 20°

    ·Effective system characteristics(above200kHz)

    ·These data are valid between20℃ and 30℃ provided the instrument has reached thermal equilibrium(about 1h after swithc-on)and the temperature variations is not more than 1 degree after calibration.

ZVRE,ZVR,ZVCE,ZVC(bidirectional network analyzers)

    ·After full two-port system errorcorrection(TOSM)

 

 ZVRE,ZVRZVCE,ZVC
Direcivity>46dB^1)>40dB^2)
Sourcematch>40dB^3)>36dB^4)
Loadmatch>46dB^1)>40dB^2)
Transmissiontracking<0.04dB<0.06dB
Reflectiontracking<0.04dB<0.06dB


产品留言

Copyright© 2003-2012  深圳市二手仪器 二手网络分析仪 二手频谱分析仪 二手信号源 微波暗室 屏蔽房 深圳仪器租赁版权所有            电话:0755-25604241 36984463 13760339695 QQ:541462613&564729178
传真:0755-25604241    地址:深圳市福田区福星路福星花园255    邮编:518031 粤ICP备11078921号-1   网站管理入口

网络推广:仪表展览网   技术支持: